力士乐HVE02.2-W018N伺服驱动器F262故障维修报价查询

发布者:HP    来源:太阳集团欢迎您     发布时间:2022-10-11

力士乐HVE02.2-W018N伺服驱动器F262故障维修报价查询

力士乐伺服驱动器维修电话:当设备出现问题的时候大家都是比较凌乱的状态,不管是上网查询还是借鉴说明书,一时间都不知道该怎么办。为了避免这种情况,当设备出现问题的时候可以联系我们上海仰光电子18964852867.

 

力士乐伺服驱动器维修报价查询:

F262故障含义:External Short at Status Outputs状态输出处的外部短路

 

Description:故障说明:

Status outputs are monitored for short circuits and thermal overload.

监控状态输出是否存在短路和热过载。

If output current exceeds 350mA for about 1μs, then this is acknowledged as a short circuit and the pertinent channel is shut off.如果输出电流超过350mA持续约1μs,则这被认为是短路,相关通道被关闭。

The output remains off unti the error is cleared.

输出保持关闭,直到错误被清除。

With thermal overload, the error is set and the output(s) shut off. After the driver has cooled off, the outputs are switched back on and so on.

热过载时,设置错误并关闭输出驱动器已冷却,输出重新打开等。

The error, however, remains until it is cleared. Thermal overload can occur if several outputs are overloaded in excess of 80 mA.但是,错误将一直存在,直到清除为止。如果多个输出过载超过80 mA,可能会发生热过载。

 

Note: Light bulbs, for example, cannot be controlled as their inrush current causes a short-circuit.注:例如,灯泡无法控制其浪涌电流会引起短路。

 

Cause:原因:

1. Short circuited outputs (X2/6, X2/7, X2/8, X2/9, X2/10, X2/20, X2/21, X2/22)

短路输出(X2/6X2/7X2/8X2/9X2/10X2/20X2/21X2/22

2. One or more outputs are overloaded.一个或多个输出过载。

Remedy:解决措施:

1. Eliminate short circuit or limit switching current (< 350 mA)

消除短路或限制开关电流(<350 mA

2. Drop current, depending on output, to < 80 mA.

根据输出,降低电流至<80 mA