贝加莱伺服驱动器1180维修报警什么32143如下?
32143: 参数数据在参数步骤大于4 个字节
Data of a parameter in a parameter sequence longer than 4 bytes
Info(UDINT): Index of this parameter in the parameter sequence
32200: 调用plAcycWrite() 错误Error at call of plAcycWrite()
Info(UINT): Status of plAcycWrite()
32201: 调用plAcycWrite() 错误Error at call of plAcycWrite()
Info(UINT): Status of plAcycWrite()
32202: 调用plAcycRead() 错误Error at call of plAcycRead()
Info(UINT): Status of plAcycRead()
32203: 调用plAcycRead() 错误Error at call of plAcycRead()
Info(UINT): Status of plAcycRead()
32204: 通过循环通道读参数超时(驱动器存在于网络?)
Timeout for parameter read via acyclic channel (exists drive in network ?)
32205: 通过循环通道写参数超时(驱动器存在于网络?)
Timeout for parameter write via acyclic channel (exists drive in network ?)
32206: 循环通道1:不管写反应读请求Cyclic channel: Read Request in spite of Wait for Response
32207: 循环通道1:不管写反应写请求Cyclic channel: Write Request in spite of Wait for Response
32500: FIFO 信息已存在The Message FIFO is already existing
32501: 创建FIFO 信息错误Error at creation of Message FIFO
贝加莱伺服驱动器1180维修:大功率伺服驱动器维修 呈限速保护状态一过电流打开变频器的散热片风机,看到散热片上也粘满了油污和杂物,将变频器的散热通道堵住。由此推断变频器的模块因散热不良导致其过保,这种直接处理后测试性能,如果性能达标,不需要更换也可以继续使用,如果性能不达标,则需要更换,不能凑合使用,以免造成大的损坏,得不偿失。
太阳集团欢迎您专业从事各知名品牌伺服驱动器维修,伺服电机维修,触摸屏维修,变频器维修,伺服器维修,伺服控制器维修,数控系统维修改造,机器人维修保养以及各种板卡,芯片级维修维护的科技型企业,免费检测,快速维修,部分立等可取!关于贝加莱伺服驱动器故障报警维修的处理方法,可以咨询太阳集团欢迎您13817011982
转载请注明出处:上海仰光电子科技专业伺服驱动器维修,伺服电机维修