力士乐伺服驱动器维修公司:上海仰光电子在力士乐REXROTH伺服维修方面已经形成一套完善的维修技术流程,拥有大部分力士乐型号维修软硬件测试系统,兼维修技术经验,经过数10多年的维修技术积累,博士力士乐维修修复率可达96%左右,现在我们主要谈谈最近针对力士乐驱动器hcs系列报E251故障维修成功案例:
博世力士乐伺服驱动器维修测试台:
E251含义:Motor Overtemperature Warning
电机过热警告
Description:
As soon as the temperwature warning threshold (145°C) is exceeded, warnig E251 is generated and the drive complies with the command value.一旦超过温度警告阈值(145°C),就会生成警告E251,驱动器符合命令值。
This state can last infinitely without a powering down occurring. Not until the temperature error threshold is exceeded will an immediate powering down take place.这种状态可以无限持续,而不会发生断电。直到超过温度错误阈值,才会立即断电。
See also F219 Motor Overtemperature Shutdown
另请参阅F219电机过热停机
Cause:原因:
The motor became overloaded. The effective torque required of the motor
was above the allowable standstill continuous torque for too long.电机过载。电机所需的有效扭矩长时间高于允许的静止持续扭矩。
Remedy:
Check the installation of the motor. For systems which have been in use
for a long time, check to see if the drive conditions have changed (in
regards to pollution, friction, components which have been moved, etc)
检查电机的安装。对于已使用的系统长时间以来,检查驱动条件是否发生了变化(在
污染、摩擦、移动的部件等)
转载请注明出处:上海仰光电子科技专业伺服驱动器维修,伺服电机维修
本文链接:/fuwu/Services_Show12101.htm