博世力士乐伺服驱动器维修案例:DKS将功能都集成在一个盒子中。Indramat DKS驱动器可以通过Sercos,模拟输入或其他几种控制卡(例如DLC单轴控制卡)进行控制。E257Continuous Current Limiting Active持续电流限制激活
Description:说明:
The drive controller sets the peak current available for 400ms.
驱动器控制器设置可用于400ms的峰值电流。
Thereafter,the continuous current limit becomes active and dynamically limits the peak current to the continuous current.此后,连续电流限制变为有效的,并且动态地将峰值电流限制为连续电流。
Cause:原因:
More continuous torque was required than was available.
所需的连续扭矩大于可用扭矩。
Remedy:处理措施:
1. Check the drive installation.
检查驱动器的安装情况。
2. Check the installation of the motor.
检查电机的安装情况。
For systems which have been in use for a long time, check to see if the drive conditions have changed (in regards to pollution, friction, components which have been moved, etc).对于长期使用的系统,检查驱动条件是否发生了变化(污染、摩擦、移动的部件等)。